APPLICATION EXAMPLE

Football field lighting with JENNY-20


For help with an application simulation using our optics, or to make a request about what application you want us to cover next, contact Tech support

SETUP:

Application: Sports field lighting
Optics: JENNY-20
Luminous flux (Luminaire): 68 klm
Number of luminaires in a pole: 20 pcs
Number of optics in a luminaire: 60 pcs
Optic grid in luminaire: 6 x 10 pcs
Number of poles: 4 pcs
Pole spacing: ~35 m
Mounting height: 12 m
Maintenance factor: 0.8

RESULTS:

Football field - horizontal. Meets the FIFA Class III (Non-televised) National game requirements.  
Average: 753 lx
Average requirement (Class III): ≥750 lx
Uo: 0.70
Uo requirement (Class III): ≥0.70
GO TO PRODUCT CARDS
F15538_JENNY-20
F15553_JENNY-8X1-20

The information contained herein is the property of LEDiL Oy, Joensuunkatu 13, FI-24100 SALO, Finland and is subject to change without notice. Please visit www.ledil.com for additional information, such as the latest photometric files, 3D mechanical models, and application notes relating to handling, gluing and taping.