APPLICATION EXAMPLE
Football field lighting with JENNY-20
For help with an application simulation using our optics, or to make a request about what application you want us to cover next, contact Tech support
SETUP:
Application: | Sports field lighting |
Optics: | JENNY-20 |
Luminous flux (Luminaire): | 68 klm |
Number of luminaires in a pole: | 20 pcs |
Number of optics in a luminaire: | 60 pcs |
Optic grid in luminaire: | 6 x 10 pcs |
Number of poles: | 4 pcs |
Pole spacing: | ~35 m |
Mounting height: | 12 m |
Maintenance factor: | 0.8 |
RESULTS:
Football field - horizontal. Meets the FIFA Class III (Non-televised) National game requirements. | |
Average: | 753 lx |
Average requirement (Class III): | ≥750 lx |
Uo: | 0.70 |
Uo requirement (Class III): | ≥0.70 |
F15538_JENNY-20 | ||
F15553_JENNY-8X1-20 |
The information contained herein is the property of LEDiL Oy, Joensuunkatu 13, FI-24100 SALO, Finland and is subject to change without notice. Please visit www.ledil.com for additional information, such as the latest photometric files, 3D mechanical models, and application notes relating to handling, gluing and taping.